Abstract
A simple, rapid, and sensitive spectrophotometric method for the determination of benzoyl peroxide (BPO) in wheat flour samples was developed. The detection principle is based on BPO reacted with 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) to obtain a blue-green colored product that was detected at 415 nm by spectrophotometry. The effect of factors influencing the color reaction was investigated. Under the selected conditions, the linear range for quantification of BPO was observed between 0.2-1.0 mg L-1 with r2 = 0.998. The limit of detection (LOD) was 0.025 mg L-1. The developed method obtained superior precision (relative standard deviation < 2%) using 11 repeatability at 0.2 mg L-1, 0.6 mg L-1, and 0.8 mg L-1. The proposed methodology was successfully applied to determine BPO in wheat flour samples. © 2015, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC.
ScienceDirect Link
Recommended Citation
Ponhong, K.; Supharoek, S.-A.; Siriangkhawut, W.; and Grudpan, K.
(2015)
"A rapid and sensitive spectrophotometric method for the determination of benzoyl peroxide in wheat flour samples,"
Journal of Food and Drug Analysis: Vol. 23
:
Iss.
4
, Article 15.
Available at: https://doi.org/10.1016/j.jfda.2015.03.006
Creative Commons License
This work is licensed under a Creative Commons Attribution-Noncommercial-No Derivative Works 4.0 License.
Fulltext URL
https://www.sciencedirect.com/science/article/pii/S1021949815000526/pdfft?md5=d003ad1f36fd934339afe32288f41376&pid=1-s2.0-S1021949815000526-main.pdf